Table of Contents

Supported Shifters

F-Series 8HP Shifter

Specifications
CAN Speed

Some examples of supported shifters part numbers (hyperlink opens crossreference):

Shifter Pinout
Pin # Description Connects to (8HP) Connects to (others)
1 - - -
2 - - -
3 PTCAN Lo CAN1 Lo CAN3 Lo
4 PTCAN Hi CAN1 Hi CAN3 Hi
5 PTCAN2 Lo CAN2 Lo -
6 PTCAN2 Hi CAN2 Hi -
7 WakeUp WUP WUP
8 GND GND GND
9 - - -
10 +12V +12V +12V

F-Series DCT Shifter

Specifications
CAN Speed

Some examples of supported shifters part numbers (hyperlink opens crossreference):

Shifter Pinout
Pin # Description Connects to (F-DCT) Connects to (8HP/E-DCT)
1 DriveLogic Button DL Button -
2 - - -
3 PTCAN Lo CAN1 Lo CAN3 Lo
4 PTCAN Hi CAN1 Hi CAN3 Hi
5 PTCAN2 Lo CAN2 Lo -
6 PTCAN2 Hi CAN2 Hi -
7 WakeUp WUP WUP
8 GND GND GND
9 - - -
10 +12V +12V +12V

When using this shifter together with 8HP, Park can be triggered by holding shifter up while in neutral.

When using this shifter together with F-DCT, DriveLogic mode changes has to be done through a button (BMW # 61317850574) connected to the shifter. A universal grounding (with resistors) button can also be used instead on pin 1. Resistance needs to be 9.4kOhm when not pressed, and 4.7kOhm when pressed. This is achievable using two 4.7kOhm resistors.

DriveLogic Button Pinout
Pin # Description Connects to (F-DCT)
1 Input from shifter Shifter pin 1
2 GND GND
3 Backlight +12V
Universal Grounding Button - Connection


G-Series 8HP Shifter

Specifications
CAN Speed
Shifter Pinout
Pin # Description Connects to (8HP G-Series) Connects to (Others)
1 - - -
2 - - -
3 PTCAN Lo CAN1 Lo CAN3 Lo
4 PTCAN Hi CAN1 Hi CAN3 Hi
5 - - -
6 - - -
7 - - -
8 GND GND GND
9 - - -
10 +12V +12V +12V

A90 Supra 8HP Shifter

Specifications
CAN Speed
Shifter Pinout
Pin # Description Connects to (8HP G-Series) Connects to (Others)
1 - - -
2 - - -
3 PTCAN Lo CAN1 Lo CAN3 Lo
4 PTCAN Hi CAN1 Hi CAN3 Hi
5 - - -
6 - - -
7 - - -
8 GND GND GND
9 - - -
10 +12V +12V +12V

E6x/7x LCI Shifter

Specifications
Shifter Pinout
Pin # Description Connects to
1 +12V +12V
2 - -
3 PTCAN Lo CAN3 Lo
4 PTCAN Hi CAN3 Hi
5 WakeUp WUP
6 GND GND
CAN Speed

—-

E84 X1 8HP Shifter

Specifications
Shifter Pinout
Pin # Description Connects to
1 +12V +12V
2 - -
3 PTCAN Lo CAN3 Lo
4 PTCAN Hi CAN3 Hi
5 WakeUp WUP
6 GND GND
CAN Speed

—-

E8x/9x x35 DCT Shifter

Specifications
CAN Speed
Shifter Pinout
Pin # Description Connects to (8HP/F-DCT) Connects to (E-DCT)
1 +12V +12V +12V
2 LIN - LIN (on DCT)
3 PTCAN Lo CAN3 Lo CAN1 Lo
4 PTCAN Hi CAN3 Hi CAN1 Hi
5 WakeUp WUP WUP
6 GND GND GND
7 Sport Button - Button
8 Sport Button - Button
9 P Supply - Park Lock
10 P Switch - Park Lock

E9x M3 DCT Shifter

Specifications
CAN Speed
Additional Features
Shifter Pinout
Pin # Description Connects to (8HP/F-DCT) Connects to (E-DCT)
1 +12V +12V +12V
2 LIN - LIN (on DCT)
3 PTCAN Lo CAN3 Lo CAN1 Lo
4 PTCAN Hi CAN3 Hi CAN1 Hi
5 WakeUp WUP WUP
6 GND GND GND
7 DriveLogic Level - - Button
8 DriveLogic Level + - Button
DriveLogic Button Pinout
Pin # Description Connects to (E9x M3 Shifter) Connects to (CANTCU)
1 GND GND GND
2 - - -
3 DriveLogic + Shifter Pin 8 Digital Input
4 Backlight +12V +12V
5 DriveLogic - Shifter Pin 7 Digital Input

E36 Shifter

Specifications

Shifter Base Pinout
Pin # Description Connects to
1 - -
2 - -
3 - -
4 - -
5 GND GND
6 - -
7 L2 DIN (E36 Shifter Pin 7)
8 L4 DIN (E36 Shifter Pin 8)

Sequential Shifter

Specifications

When using this type of shifter, there are three inputs necessary:

Additionally, Shifter N can be used to trigger Neutral gear at any given time.

Shifter Mode changes between Auto/Manual modes.


Universal DIN/CAN

Specifications

When using this type of shifter, there are five inputs necessary:

Shifter Mode changes between Auto/Manual modes.


CANTCU CAN-Keypad

CAN-keypad manufactured by Blink Marine and preconfigured for use with CANTCU (J1939). Buttons can be defined for various functions in CANTCU Configurator.

CAN Speed
Keypad Pinout
Pin # Description Connects to
1 CAN Lo CAN3 Lo
2 CAN Hi CAN3 Hi
3 GND GND
4 +12V +12V

E46 M3 Shifter

Specifications
Requirements


F90 M5 8HP Shifter

Specifications
F90 M5 shifter DriveLogic button

When using the F90 M5 shifter with 8HP, the DriveLogic button on the shifter will control the 8HP drive modes (ECO Pro/Comfort/Sport/Sport+). When used with a DCT, the DriveLogic mode can be adjusted.

CAN Speed
Shifter Pinout
Pin # Description Connects to
1 - -
2 - -
3 PTCAN Lo CAN3 Lo
4 PTCAN Hi CAN3 Hi
5 - -
6 - -
7 - -
8 GND GND
9 - -
10 +12V +12V